12
3.5.8 FUZE 12VDC
10A delay action fuze for the internal 12VDC power supply.
3.5.9 POW ER CONNECTOR
Allows you to connect the power supply of the Wave Flamer. The internal mains supplies are meant
for 110VAC to 230VAC.
3.5.10 FUZE 230VAC
10A delay action fuze for the 230VAC power supply.
3.5.11 SW IVEL HEAD AND ELECT RICAL IGNITION
Here you can find the motorized swivel head of the Wave Flamer, as well as the socket for the nozzle
and the electrodes for the electrical ignition.
3.5.12 INTERNAL 10L FLUID CANISTER
Only found in the standard variant. Here you can find the internal, reusable canister for liquid fuels.
The maximum liquid capacity is 10 Liters.
3.5.13 LEAD THROUGH FOR EXTERNAL FLUID CANISTER
Only found in the standard variant. An extension hose (sold separately) can be lead through this
opening and be attached to an external fluid tank.
3.5.14 LEVEL INDICATOR
Only found in the standard variant.Allows you to gauge the fuel level of the internal canister.
3.5.15 CONNECTOR FOR EXTERNAL PUMPING UNIT
Only found in the head variant without internal pumping unit. This special variant of the Wave Flamer,
without internal canister and pumping unit, allows you to connect an external pumping unit via a fitting
hose to the quick coupling at the front panel.
The maximum use pressure should not be higher than 14 bars.