Curtiss-Wright | TRITEX II AC 75 Rev. K PN61928 7/12/2022
11
CE Declaration of Conformity
The Tritex II 75 mm Linear and Rotary Actuators are marked with the
“Conformité Européenne Mark” (CE Mark) after passing a rigorous set of
design and testing criteria. This label indicates the product meets
applicable electrical safety, and electromagnetic immunity and emissions
(EMC) standards when installed according to the installation instructions.
The conditions of acceptability required for CE are:
•
Drive input maximum continuous operating ratings:
Input Voltage (all models): 240 VAC, 1
Ф
, 50/60 Hz
Drive/Motor Model
Stator
Input Continuous
Current (Arms)
T2M/R2M/R2G 075
1 Stack Stator
4.3
T2M/R2M/R2G 075
2 Stack Stator
4.0
T2M/R2M/R2G 075
3 Stack Stator
3.6
•
Above full load ratings are at a maximum surrounding air
temperature of 40°C.
•
Field installation power connection wires: Use 2.5mm², 300 VAC
minimum rating, and 105º C minimum rating copper wires.
•
Two externally connected ground wires must be used and connected
to protective earth ground (PE). Note: two PE connection terminals
are provided since touch is greater than 3.5mA. This wire is required
to be no less 2.5mm² since mechanical protection of is provided via
hard conduit or a cable assembly.
•
This product is suitable for use on a circuit capable of delivering up
to 10,000 rms symmetrical amperes, 240 volts maximum, when
protected with by a Class RK1 or Class CC fuse or Inverse Time
Circuit Breaker, rated at 15 Arms.
•
All cables must be shielded, with the outer shield bonded to
the case.
•
When using cable glands use glands that connect the braided shield
of the cable directly to enclosure.
•
When using connectors ensure that the outer shield of the cable is in
full contact with the connector housing. Connector housings must
conductive.
Summary of Contents for Curtiss-Wright Tritex II Series
Page 10: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 9 UL Certificate of Compliance...
Page 11: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 10...
Page 14: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 13...
Page 15: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 14...
Page 18: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 17...
Page 19: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 18...
Page 74: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 73 T2IPC xxx Power Cable...
Page 75: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 74 TTICO xxx Communications Cable...
Page 77: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 76 Braking Resistor T2BR1...