![Exlar Curtiss-Wright Tritex II Series Installation And Service Manual Download Page 55](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ii-series/curtiss-wright-tritex-ii-series_installation-and-service-manual_2450854055.webp)
Curtiss-Wright | TRITEX II AC 75 Rev. K PN61928 7/12/2022
54
Analog Output
A 0-10 V analog output is provided. The function of this output is
programmable. It can be used for position, velocity or current monitoring
.
The intent of this output is to provide a “monitor” type value not a
“control” value, meaning the performance is not intended for the user to
close a high speed position loop around this signal.
The Analog Reference terminal should only be connected when used
with an isolated or differential input. DO NOT CONNECT TO A
GROUNDED POINT EXTERNALLY!
Analog Current Output Specifications
Description
Specification
Current Output Range
0 - 10 V
Load Range
20 kΩ min
Output resolution
11 bits
Communications
Serial communication to the actuator is provided through the 8 mm
communication connector on the front of the actuator and also via
terminal connection on J5 under the access cover. The serial interface is
two wire RS485 network and is isolated from AC power as well as other
IO circuits. The actuator supports the Modbus RTU protocol for access to
all drive parameters (see Modbus Parameter Reference). The Defaults
are settings are: Baud Rate19.2k, Even Parity, Modbus ID address is 1.
+ 14V
Summary of Contents for Curtiss-Wright Tritex II Series
Page 10: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 9 UL Certificate of Compliance...
Page 11: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 10...
Page 14: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 13...
Page 15: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 14...
Page 18: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 17...
Page 19: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 18...
Page 74: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 73 T2IPC xxx Power Cable...
Page 75: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 74 TTICO xxx Communications Cable...
Page 77: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 76 Braking Resistor T2BR1...