Curtiss-Wright | TRITEX II AC 75 Rev. K PN61928 7/12/2022
27
•
If manually driving with a brake engaged or high force is
necessary, please consult Exlar Application Engineering.
•
If a power tool is used to operate the manual side drive the speed
should be limited to 600 RPM
•
An impact driver should never be used to operate the manual
side drive.
•
Determine end of stroke of actuator or system and do not apply
force past it.
•
Refer to
Table 1
for maximum torque specifications.
9. The T2M/X, R2MG 075 actuators have conduit hole plugs to cover
unused conduit entries, verify they are all tight.
Manual Drive Operating Instructions
Isolate all sources of energy to prevent safety hazard
due to unexpected motion
System design and operating procedures must ensure that
the drive will have no unintended motion that can create a hazard to
personnel when operating the drive manually. This includes electrical
energy turning the motor as well as energy stored in a vertical load or
spring.
There are two manual drive options available on the Tritex, Hand
Wheel (HW) and Side Drive (SD)
The hand wheel option includes an internal switch that is closed when
the hand-wheel drive is fully disengaged and opens when an attempt is
made to engage the hand wheel drive. This switch is in series with the
actuator over-temperature sensor to form a combined run permissive
signal. When manual drive is engaged, an Actuator Over-temperature
fault occurs. The fault action for this fault will disable the drive.
This function is not safety rated, so is not usually sufficient to ensure
safety. Power to the drive must be isolated before manually operation.
The Side Drive does not include and interlock switch so power must
be removed before use.
Important information to avoid damage to the manual
drive
WARNING
CAUTION
Summary of Contents for Curtiss-Wright Tritex II Series
Page 10: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 9 UL Certificate of Compliance...
Page 11: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 10...
Page 14: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 13...
Page 15: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 14...
Page 18: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 17...
Page 19: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 18...
Page 74: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 73 T2IPC xxx Power Cable...
Page 75: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 74 TTICO xxx Communications Cable...
Page 77: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 76 Braking Resistor T2BR1...