![Exlar Curtiss-Wright Tritex II Series Installation And Service Manual Download Page 62](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ii-series/curtiss-wright-tritex-ii-series_installation-and-service-manual_2450854062.webp)
Curtiss-Wright | TRITEX II AC 75 Rev. K PN61928 7/12/2022
61
Important Note for units built before 2016:
If the battery is removed with both Motor and Logic power also removed,
do
not
reconnect the battery and leave all power
off
for
4 minutes
.
Once all power is removed from the battery backed logic it must be
allowed enough time to completely bleed down before restarting. Once
power is re-applied the home position must be reestablished.
Travel limitations:
The counter has a range of +/- 4096 motor revolutions;
therefore the actuator must operate within this range. If
the actuator is moved beyond this point a Position Tracking Fault will
occur on the subsequent power up. The only way to reset this fault is to
remove the battery connection for about 20 seconds with all power AC
,and Auxiliary DC if used, removed. On the subsequent power up the
fault can be cleared and the home position must be re-established.
Ethernet Options, EIP, TCP or ProfiNet IO
The Ethernet Options EIP, PIO,or TCP in the model mask provide an
Ethernet rated M12 connector for connection to the Network at the rear
of the actuator.
An IP 67 4-pole M12 D coded connector is used, this type of connector
must only be used with two pair cables. When the Ethernet connection is
made via an Ethernet switch or hub a straight through cable set must be
used. If there is a single node connection direct from the Ethernet
PC/PLC to the Tritex then a crossover cable may be required. Some PC
Ethernet cards have capability to detect a crossover connection.
See Expert Software manual for setup of Tritex Ethernet parameters and
Ethernet/IP or ProfiNet IO manuals for network specific setup
information.
Cord sets
CAUTION
Signal Name
1
Tr (TX+)
Pair
2
Pin
3
R (RX+)
Pair
4
Receive - (RX-)
Summary of Contents for Curtiss-Wright Tritex II Series
Page 10: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 9 UL Certificate of Compliance...
Page 11: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 10...
Page 14: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 13...
Page 15: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 14...
Page 18: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 17...
Page 19: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 18...
Page 74: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 73 T2IPC xxx Power Cable...
Page 75: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 74 TTICO xxx Communications Cable...
Page 77: ...Curtiss Wright TRITEX II AC 75 Rev K PN61928 7 12 2022 76 Braking Resistor T2BR1...