58
P
RODUCT
M
ANUAL
1009541
Chapter
8
S
PECIFICATIONS
DC Voltages
The internal tape drive operates from st5 and +12 VDC supply
voltages (all specified voltages are DC, no external AC power is used).
Table 8-8
defines the power specifications.
Note:
The VXA-2 tape drive does not provide overvoltage or overcurrent
protection, except for TERMPWR, which has a resettable fuse. Safety
agency certification per IEC-950 requires that the supplied voltages be
from a Safety Extra-Low Voltage source.
Power Consumption
Table 8-9
shows the internal drive’s power consumption when operating and
when idle.
Table 8-8
Power specifications (internal model)
Power
+5 Volts
+12 Volts
Required supply tolerance:
±
5%
±
10%
Ripple and noise: (50 Hz to
20 MHz)
a
125 mVpp max.
125 mVpp max.
Operating current (amps)
Read or write:
1.0 (average)
1.03 (peak)
0.37 (average)
0.37 (peak)
Search/high speed:
0.94 (average)
1.08 (peak)
0.46 (average)
2.08
b
(peak)
Load/unload:
0.90 (average)
1.10
c
(peak)
0.39 (average)
2.10
d
(peak)
Power up:
0.80 (average)
1.25
e
(peak)
0.10 (average)
0.52
f
(peak)
Idle:
0.88 (average)
—
0.06 (average)
—
a
The ripple voltage is included in the total voltage tolerance.
b
1.8 seconds maximum.
c
0.15 seconds maximum.
d
1.4 seconds maximum.
e
0.6 seconds maximum.
f
1.1 seconds maximum.
Table 8-9
Power consumption (internal model)
Power Consumption
Power (average)
Read or write:
9.5 watts
Search/high speed:
10.3 watts
Load/unload:
9.2 watts
Power up:
5.2 watts
Idle:
5.2 watts
Summary of Contents for VXA-2