1 Technical
data
1/1
1.1 TRITON
260
TRITON
260
Setting range:
Welding current / voltage
TIG,
MMA
MIG/MAG
5A/ 10.2V – 260A/ 20.4V
5A/ 20.2V – 230A/ 29.2V
5A/ 14.3 – 240A/ 26V
Max. welding current at
TIG MMA
MIG/MAG
20ºC ambient temperature:
50%DC
60%DC
100%DC
40ºC ambient temperature:
25%DC
35%DC
60%DC
100%DC
260A
240A
190A
260A
230A
170A
130A
230A
210A
160A
230A
200A
150A
110A
240A
220A
170A
240A
210A
160A
120A
Load alternation
10min (60% DC
∧
6 min welding, 4min break)
Open circuit voltage
93V
Mains voltage (tolerances)
3 x 400V (-25% - +15%)
3 x 415V (-25% - +10%)
Frequency
50/60 Hz
Mains fuse (safety fuse - slow-blow)
3 x 16A
Mains connection lead
4 x 1.5mm
2
Max. connected power
10.8kVA
Recommended generator rating
14.6kVA
cos
ϕ
/ efficiency
0.99 / 89%
Insulation class / Protection
classification
H / IP 23
Ambient temperature
-10
°
C to +40
°
C
Machine cooling / Torch cooling
Fan / Gas
Workpiece lead
35mm
2
Dimensions L/W/H [mm]
560 x 245 x 365
Weight
approx. 24.5Kg
constructed to standard
IEC 60974 / EN 60974 / VDE 0544
EN 50199 / VDE 0544 Teil 206
/
Summary of Contents for TRITON 260 DC