3 Function
specification
3/13
3.7 Remote
control
Only the remote controls described in these operating instructions should be connected.
Plug in and lock the remote control to the remote control connection socket only, and only
when the welding machine is switched off (chap. 2.1.1, G1 for TRITON 260 and chap. 2.2.1,
G3 for TRITON 400/500). The remote control must never be connected to a wire feed unit.
See the operating instructions for the remote control for more detailed information.
Foot-
operated
remote control RTF 1
Manual remote control RT1
Functions:
•
Welding current "ON/OFF"
(switches on after the pedal
has been pressed).
•
Infinitely adjustable welding
current (in %) depending on
the preselected main
current or I
1
of the welding
machine.
Functions:
•
Infinitely adjustable welding
current (in %) depending on
the welding current I
1
preselected on the welding
machine.
When the foot-operated remote control
RTF 1 is connected, the machine
switches automatically to non latched
operation. Up- and Down-Slope will be
switched off.
RTP 1 manual remote control
RTP 2 manual remote control
RT P 1
t
1
t
1
I
1
I
1
I
1
I
1
I
2
I
2
t
1
t
1
t
2
t
2
0
50
75
100
25
0
25
50
75
100
t (sek)
2
t (sek)
2
0,05
0,5
1
1,5
2
t (sek)
1
t (sek)
1
x10
0,05
0,5
1
1,5
2
I
1
I
1
I
2
I
2
I
1
I
1
(% AMP)
(% I )
1
(% I )
1
I
2
I
2
Functions:
•
TIG / MMA
•
Pulse / spot / normal
•
The percentage settings
of the main and
secondary current
depending on the
preselected welding
current I
1
of the welding
machine.
•
Pulse, spot and break
times are infinitely
adjustable.
RT P 2
t
1
t
1
I
1
I
1
0
50
75
100
25
0
25
50
75
100
2,5
5
7,5
10
12,5
15
Hz
sec
x10
x100
x10
x100
x0,1
x1
x0,1
x1
17,5
20
22,5
25
Balance
%
Balance
%
10
30
50
70
90
250-2500
0,25-2,5
0,25-2,5
25-250
2,5-25
2,5-25
Hz /
sec
Hz /
I
1
I
1
I
2
I
2
Hz
I
1
I
1
I
2
I
2
I
1
I
1
(% AMP)
(% I )
1
(% I )
1
I
2
I
2
Functions:
•
TIG / MMA
•
Pulse / spot / normal
•
The percentage settings of
the main and secondary
current depending on the
preselected welding current I
1
of the welding machine.
•
Frequency and spot times
infinitely adjustable.
•
Coarse adjustment of the
cycle frequency.
•
Pulse/break ratio (balance)
adjustable from 10% to 90%.
•
For remote controls RTP 1 and RTP 2, adjust the following settings on the appropriate
changeover switch:
TIG
MMA
Summary of Contents for TRITON 260 DC
Page 57: ...10 Circuit diagram 10 1 10 1 TRITON 260 Circuit diagrams are also in the machine...
Page 58: ...10 Circuit diagram 10 2...
Page 59: ...10 Circuit diagram 10 3 10 2 TRITON 360 500 Circuit diagrams are also in the machine...
Page 60: ...10 Circuit diagram 10 4...
Page 61: ...10 Circuit diagram 10 5...