1 Technical
data
1/2
1.2 TRITON
400/500
TRITON 400
TRITON 500
Setting range:
Welding current / voltage
TIG,
MMA
MIG/MAG
5A/ 10,2V - 400A/ 26,0V
5A/ 20,2V - 400A/ 36,0V
5A/ 14,3V - 400A/ 30,0V
5A/ 10.1V -500 A/ 30.0V
5A/ 20.1V -500A/ 40.0V
5A/ 14.2V -500A/ 39.0V
Duty cycle at 40°C ambient temperature:
40%dc
60%dc
100%dc
Duty cycle at 20°C ambient temperature:
40%dc
45%dc
60%dc
65%dc
100%dc
400A
360A
300A
-
400A
-
360A
300A
500A
450A
340A
500A
-
475A
-
390A
Load alternation
10min (60% DC
∧
6 min welding, 4min break)
Open circuit voltage
92V 79V
at
400V
91V at 460V
Mains voltage (tolerances)
3 x 400V (-25% - +20%)
3 x 460V (-25% - +15%)
3 x 400V (-25% - +20%)
3 x 460V (-25% - +15%)
3 x 415V (-25% - +10%)
Frequency
50/60 Hz
Mains fuse (safety fuse - slow-blow)
3 x 35A
Mains connection lead
4 x 4mm
2
Max. connected power
21,5kVA 29
kVA
Recommended generator rating
29,0kVA 39.2kVA
cos
ϕ
/ efficiency
0.99 / 89%
Insulation class / Protection
classification
H / IP 23
Ambient temperature
-10
°
C to +40
°
C
Machine cooling / Torch cooling
Fan / Gas
Workpiece lead
70mm
2
95mm
2
Dimensions L/W/H [mm]
625 x 335 x 560
Weight
approx. 55kg
approx. 58Kg
constructed to standard
IEC 60974 / EN 60974 / VDE 0544
EN 50199 / VDE 0544 Teil 206
/
Summary of Contents for TRITON 260 DC
Page 57: ...10 Circuit diagram 10 1 10 1 TRITON 260 Circuit diagrams are also in the machine...
Page 58: ...10 Circuit diagram 10 2...
Page 59: ...10 Circuit diagram 10 3 10 2 TRITON 360 500 Circuit diagrams are also in the machine...
Page 60: ...10 Circuit diagram 10 4...
Page 61: ...10 Circuit diagram 10 5...