3 Function
specification
3/12
3.6.2 TRITON
400/500
In MIG/MAG welding, only the following operating and display elements on the welding
machine are active:
•
The digital display (D1),
•
the welding voltage or current changeover switch display (C1),
•
the roatry dial characteristic line (B3),
•
Rotary switch Dynamic correction / choke effect setting.
8 permanently programmed characteristic lines are stored for MIG/MAG welding. These can
be called up in 8 levels.
The type of material, wire diameter and type of gas are stored in one characteristic line.
Setting is with the aid of the outer scale and can be done before the welding operation.
Characteri-
stic line
number
Material Wire
diameter
(mm)
Type of
gas
1
FCAW (cored wire)
0.9 – 1.2
2
G3/4Si1 (low-alloy steel)
0.8 – 1.0
Ar/Mix
3
G3/4Si1 (low-alloy steel)
1.2 – 1.6
Ar/Mix
4
G3/4Si1 (low-alloy steel)
0.8 – 1.0
CO
2
100%
5
G3/4Si1 (low-alloy steel)
1.2 – 1.6
CO
2
100%
6
CrNi (high-alloy steel)
0.8
various
7
CrNi (high-alloy steel)
1.0 – 1.6
various
8
Al/Cu (aluminium or
copper
alloys)
1.0 – 1.6
Ar 100%
Summary of Contents for TRITON 260 DC
Page 57: ...10 Circuit diagram 10 1 10 1 TRITON 260 Circuit diagrams are also in the machine...
Page 58: ...10 Circuit diagram 10 2...
Page 59: ...10 Circuit diagram 10 3 10 2 TRITON 360 500 Circuit diagrams are also in the machine...
Page 60: ...10 Circuit diagram 10 4...
Page 61: ...10 Circuit diagram 10 5...