Design and function
Machine configuration menu
96
099-005444-EW501
17.03.2015
ENTER
EXIT
NAVIGATION
l
0
l
0
Prog
VOLT
kW
+
drive
4
X
LP
+
Figure 5-56
Display
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Lead resistance 2
Lead resistance for the second welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Only qualified service personnel may change the parameters!
Time-based power-saving mode
• 5 min.–60 min. = Time to activation of power-saving mode in case of inactivity.
• off = inactivated