Machine description
– quick overview
Machine control
– Operating elements
24
099-005444-EW501
17.03.2015
4.4.1
Functional sequence
Figure 4-5
Item Symbol
Description
0
1
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
2
Signal light, gas pre-flow time
Setting range 0.0 s to 20.0 s
3
Signal light, start program (P
START
)
• Wire speed:1% to 200% of the main program P
A
• Correction of the arc length -9.9 V to +9.9 V
4
sec
Signal light, start time
Setting range, absolute 0.0 s to 20.0 s (0.1 s increments)
5
sec
Signal light, slope time program P
START
to main program P
A
Setting range 0.0 s to 20.0 s (0.1 s increments)
6
Signal light, main program (P
A
)
• Wire speed WF-min. to WF-max.
• Correction of the arc length -9.9 V to +9.9 V
7
sec
Signal light, duration of main program P
A
Setting range 0.1 s to 20.0 s (0.1 s increments).
Used e.g. in connection with the super pulse function
8
Signal light, reduced main program (P
B
)
• Wire speed:1% to 200% of the main program P
A
• Correction of the arc length -9.9 V to +9.9 V
9
sec
Signal light, duration reduced main program P
B
Setting range 0.0 s to 20.0 s (0.1 s increments).
Used e.g. in connection with the super pulse function.
10
sec
Signal light, slope time program P
A
(or P
B
)
to end program P
END
Setting range 0.0 s to 20.0 s (0.1 s increments)
11
Signal light, end program (P
END
)
• Wire speed:1% to 200% of the main program P
A
• Correction of the arc length -9.9 V to +9.9 V
12
sec
Signal light, duration of end program P
END
Setting range 0.0 s to 20.0 s (0.1 s increments)
13
Signal light, gas post-flow time
Setting range 0.0 s to 20.0 s
14
Super-
puls
Signal lamp, super pulse function
Lights up when the super pulse function is active.