Maintenance, care and disposal
Maintenance work, intervals
100
099-005444-EW501
17.03.2015
6.2.2
Monthly maintenance tasks
6.2.2.1 Visual inspection
• Casing damage (front, rear and side walls)
• Wheels and their securing elements
• Transport elements (strap, lifting lugs, handle)
• Check coolant tubes and their connections for impurities
6.2.2.2 Functional test
• Selector switches, command devices, emergency stop devices, voltage reducing devices, message
and control lamps
• Check that the wire guide elements (inlet nipple, wire guide tube) are fitted securely.
6.2.3
Annual test (inspection and testing during operation)
The welding machine may only be tested by competent, capable personsl. A capable person is
one who, because of his training, knowledge and experience, is able to recognise the dangers
that can occur while testing welding power sources as well as possible subsequent damage and
who is able to implement the required safety procedures.
For more information refer to the "Warranty registration" brochure supplied and our information
regarding warranty, maintenance and testing at
www.ewm-group.com
!
A periodic test according to IEC 60974-4 "Periodic inspection and test" has to be carried out. In addition
to the regulations on testing given here, the relevant local laws and regulations must also be observed.