Design and function
MIG/MAG welding
66
099-005444-EW501
17.03.2015
5.10.10 Main program A mode
Different welding tasks or positions on a workpiece demand various welding performances (operating
points) or welding programs. The following parameters are stored in each of the up to 16 programs:
• Operating mode
• Welding type
• Superpulses (ON/OFF)
• Wire feed speed (DV2)
• Voltage correction (U2)
• Dynamics (DYN2)
The user can change the main program welding parameters using the following components.
Progra
m
switching
JOB
s
witchi
ng
Progra
m
Opera
ting
mod
e
superPul
s
Wire spe
ed
Vol
ta
ge
corre
c
tion
Dy
na
m
ic
s
M3.7x
Wire feeder control
Yes
Yes
P0
Yes
Yes
Yes
P1...15
Yes
R20
Remote control
Yes
No
P0
No
Yes
No
P1...9
Yes
1)
R40
Remote control
Yes
No
P0
No
Yes
Yes
No
No
R50
Remote control
Yes
No
P0
Yes
Yes
P1...15
PC 300.NET
Software
No
No
P0
Yes
No
P1...15
Yes
Up/Down
Welding torch
Yes
No
P0
No
Yes
No
P1...9
No
2 Up/Down
Welding torch
Yes
No
P0
No
Yes
No
P1...15
No
PC 1
Welding torch
Yes
No
P0
No
Yes
No
P1...15
No
PC 2
Welding torch
Yes
Yes
P0
No
Yes
No
P1...15
No
1) in case of correction mode, refer to Special parameters "P7