HPS-C - TS operating instructions
Page 11 / 32
"Table" menu
Display
Unlike the "Display" menu, all zones are displayed row by row in tabular form. Apart from the most important process data;
actual temperature, set value and output power, other values are also available. The display is intended as an alternative to
single window display and if the operator wishes can be equally used.
The following information per zone is displayed in the "Table" menu:
•
"No"
Zone number within the overall system
•
"Name"
Name of the zone
•
"Temp."
Current actual temperature value
•
"Set value"
Set value
•
"Actual value"
Current output power in % (230V operation) or A (5V operation)
•
"Type"
Operating voltage of the hotrunner: 230V or 5V
•
"Controller"
Operating mode of the zone: Temperature controlled (°C) or manually specified control variable
(% or A)
•
"Current 230V"
Maximum current through the heating conductor or input current of the 5V transformer
•
"Increase"
Set value for increase mode (setting in the "Parameters" menu)
•
"Decrease"
Set value for decrease mode (setting in the "Parameters" menu)
After selecting the required zones, however, only the set value can be changed in this menu.
Unlike the window display, in the tabular display of the progression of the process only 20 zones per page are displayed; the
scroll bar on the right-hand edge of the screen is used to page down.
Further, the actual value is not highlighted in colour if it differs from the set value.
Zone selection / grouping
Selection and grouping of zones and adjusting set values is carried out analogous to the "Display" menu. However, instead
of the zone window the corresponding row must be selected.
Alarm messages
The display of alarm messages and opening of the alarm window is analogous to the "Display" menu. However, instead of a
red frame faulty rows are completely highlighted in red.