HPS-C - TS operating instructions
Page 30 / 32
230V load connection
16-pin socket insert for up to 8 heaters
Zone Contact
1
1 + 9
2
2 + 10
3
3 + 11
4
4 + 12
5
5 + 13
6
6 + 14
7
7 + 15
8
8 + 16
24-pin socket insert for up to 12 heaters
Zone Contact
1
1 + 13
2
2 + 14
3
3 + 15
4
4 + 16
5
5 + 17
6
6 + 18
7
7 + 19
8
8 + 20
9
9 + 21
10
10 + 22
11
11 + 23
12
12 + 24
In controllers with a larger number of zones the other connector plugs are assigned according to the first
connector plugs.
E.g.: For controller 68010.240 (36 zones) Zone 13 is applied to contacts 1 + 13 of the second connector plug, Zone
25 to contacts 1 + 13 of the third connector plug.