54
01-2018 5035 01
boilEr
paramEtErs
Sets the operating parameters of the
boiler(s).
-Temperature: sets the operating tempera-
ture of the boiler.
-Minimum temperature for dispensing bev-
erages: sets the minimum temperature for
making beverages available.
If the boiler temperature is lower than the
temperature that has been set, a “low tem-
perature” error message will be displayed.
With the "Temperature threshold" and "Min-
utes” parameters, the boiler’s temperature
maintenance cycle can be set.
For example, if no beverages are dis-
pensed during the set minutes, the temper-
ature of the water in the boiler is increased
by the degrees set in the "Temperature
threshold".
moDEls
witH
a
cappucciNo
makEr
-Steam boiler pressure: set the steam
boiler pressure value.
For each pressure value, the appliance
displays the corresponding temperature.
-Minimum steam boiler pressure: sets the
minimum pressure for making beverages
which require steam available.
If the boiler pressure is lower than the
pressure that has been set, a “low pres-
sure” error message will be displayed.
For each pressure value, the appliance
displays the corresponding temperature.
mixEr
aNti
-
lock
Sets how long after the last instant selec-
tion to briefly activate the mixers (anti-lock
function).
The function is useful if instant powder resi-
dues remain in the mixers.
.
motor
-
DrivEN
rEgulatioN
of
griNDiNg
wHEEls
In the equipment, where the regulation of
grinding wheels is motor-driven, you can
regulate grinding (coarse or finer).
Set up the value (expressed in 1/6 of a turn
of the grinding wheel ring nut) to bring the
grinding wheels closer or to move them
farther.
When grinding wheels are brought closer,
grinding is finer.
When grinding wheels are moved farther,
grinding is coarser.
Act manually on the regulation knob of the
grinder for the machines where the regula-
tion of grinding wheels is not motor-driven.