Bitrate High:
This Fault is triggered when the bit rate of the stream rises above a set threshold.
•
Error Duration (Seconds):
The error duration controls how many seconds of bitrate below
specified threshold that must pass before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of bitrate above
specified threshold that must pass before the fault is cleared.
PID Loss:
If video program ID (PID) is missing in the input transport stream the PID Loss fault will trigger.
•
Error Duration (Seconds):
The error duration controls how many seconds of that video PID is
detected as missing must elapse before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of valid video PID
detection must elapse before the fault is cleared
Commercial Insertion Flag:
This fault will be triggered when MViP-II receives a SCTE-35 commercial
insertion flag. The fault will trigger when each flag is received.
Audio Loss:
Audio loss is detected when no valid audio data can be decoded.
•
Error Duration (Seconds):
The error duration controls how many seconds of audio that cannot be
decoded must elapse before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of audio that cannot
be decoded must elapse before the fault is cleared.
Audio Scrambled:
If audio is detected as scrambled or encrypted then the audio fault will trigger.
•
Error Duration (Seconds):
The error duration controls how many seconds of audio that is
detected as encrypted must elapse before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of audio that is
detected as encrypted must elapse before the fault is cleared.
Audio low:
This Fault is triggered when the dBFS value of the audio channel monitored falls below a set
dBFS threshold. Audio Low alarms can be configured on each audio channel monitored.
•
Error Duration (Seconds):
The error duration controls how many seconds of audio detected
below the set threshold must elapse before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of audio detected
above the set threshold must elapse before the fault is cleared.
Threshold (dBFS):
The threshold is the target Decibel Full Scale value
Audio high:
This Fault is triggered when the dBFS value of the audio channel monitored rises above a set
dBFS threshold. Audio Low alarms can be configured on each audio channel monitored.
•
Error Duration (Seconds):
The error duration controls how many seconds of audio detected
above the set threshold must elapse before the fault is triggered.
•
Reset Duration (Seconds):
The error duration controls how many seconds of audio detected
below the set threshold must elapse before the fault is triggered.