5782DEC
Professional H.264 and MPEG-2 Decoder
Page - 42
Revision 1.0
WEBEASY
5.10. INBAND CONTROL
Figure 5-13: WebEASY
®
– Inband Control Tab
Inband Control
Time Source Select:
This parameter allows the user to set the time source to be used when
checking if a firmware upgrade is needed for an upgrade image with a timestamp.
Boot Image Number:
This parameter allows the user to set the image number to boot the next time
a reboot is triggered.
Overwrite Image Number:
This parameter allows the user to set the image number to overwrite
when doing a webpage or VLPro upgrade.
Current Image Number:
This parameter returns the image number that is currently running.
Time Zone Offset:
This parameter allows the user to set the time zone offset, for GMT, to apply to
the external NTP and local clock time sources.
Daylight Savings Time:
This parameter allows the user to set if daylight savings time should be
enabled when using the external NTP or local clock source.
Group ID:
This parameter sets the Group ID number for the device ID used for inband purposes.
Upgrade Status:
This parameter returns the status for inband firmware upgrades.
Upgrade Time:
This parameter returns the time pending for inband firmware upgrades.
Image Name:
This parameter displays the upgrade image names that are currently written to flash.