5782DEC
Professional H.264 and MPEG-2 Decoder
Page - 10
Revision 1.0
VLPRO INTERFACE
Decoder Reboot:
This control allows the user to power cycle the decoder.
Load Factory Configuration:
This control allows the user to soft reset the decoder to the factory
settings.
Control Port:
Currently unused on 5782DEC platform.
Data Port <1,2> Control
IP Address:
This control allows the user to set the IP address on the Data Port. This control will also
display the currently set IP address.
Netmask:
This control allows the user to set the Netmask for the Data Port IP address. This control
will also display the currently set Netmask.
Gateway:
This control allows the user to set the Gateway for the Data Port. This control will also
display the currently set Gateway.
Data Port <1,2> Monitor
SFP Part Number:
This parameter returns the part number of the SFP located in the Data Port.
Port Link Status:
This parameter returns the link status for the data port, communicating to the user
whether the link is up or down.
Port Link Info:
This parameter returns the link status for the data port, containing information about
speed and duplex.
Receive Bandwidth:
When the link is Up, this parameter returns the receive bandwidth currently
being read on the Data Port. Reading is in kbps.
Transmit Bandwidth:
When the link is Up, this parameter returns the transmit bandwidth currently
being sent on the Data Port. Reading is in kbps.
Syslog Configuration
Syslog is a valuable tool for debugging the device operation. It is essentially serial readouts over IP,
sent to a dedicated server. If issues are present, Evertz can help install and setup a syslog server for
constant monitoring of the device activity.
External Syslog:
This parameter allows the user to enable or disable sending syslog information to
the configured external server.
Syslog Server IP:
This parameter allows the user to assign the external syslog server IP address.
This will be the address of a PC with the syslog server software installed (e.g. Kiwi Syslog Server).
Temperature
Temperature Monitor:
This displays the temperature of the module.