26
ENGLISH
9.2.14 Continuous Hard Freezing
To start the cycle proceed as follows:
►
Make sure the display is in the “ON” mode.
►
Make sure the keyboard is not locked and no procedu-
re is currently under process.
►
Press and release the
(1), press and release
the
(2) key, then press and release twice the
(3)
key: until the icon
is shown on the display.
►
The display will show the operating setpoint during the
freezing process.
►
Press and release the MENU key, then press and release the key
or the key
to select
the running temperature during the freezing process, other than the set one.
►
Press and release the key
or the key
to modify this value then the ESC key to save it.
Program: MANUAL
Elapsed time: 0 min
INF
►
Press and release the START / STOP key (1): the cycle
will start.
►
During the freezing process the display will show the
cell temperature, the name of the program (if any) and
the time elapsed since the starting of the freezing pro-
cess.
►
Hold the START/STOP key pressed for 3 seconds to
stop the cycle.
9.2.15 Pre-cooling
Each running cycle can be preceeded by a precooling process.
To start the precooling cycle proceed as follows:
►
Make sure the display is in the “ON” mode.
►
Make sure the keyboard is not locked and no procedu-
re is currently under process.
►
Press and release the
(1) key, then press and
release the START / STOP key (2).
►
Hold the START/STOP key pressed for 3 seconds to