TCP/IP Network Access Controller
11
2.3.1
RS232
Terminal 29-33 signifies RS232 reader.
Figure 2-1 Connecting to the reader using RS232 format
2.3.2
Wiegand (Self-adaptive)
Terminal 34-38 signifies Wiegand reader. The controller will automatically adjust to the
Wiegand format of the card reader.
Figure 2-2 Connecting to the reader using Wiegand format
The EFC301F controller can provide 12 VDC voltage for two card readers. Twisted cable is
recommended to connect the controller and card readers.
Note:
The EFC301F controller can connect up to two readers. The Main Reader terminal,
designed for connecting to the RS232 reader, allows the controller to display the
management user interface on the LCD display of the reader. Therefore, it is required to
connect an EverFocus RS232 reader with LCD display to the Main Reader terminal. The
AUX Reader terminal is only for connecting to the Wiegand reader for indicating the door
status and alarm signals.
1
2
A B C
D E F
3
G H I
4
J K L
5
6
M N O
7
PQRS
T U V
WXYZ
*
0
#
Red
Black
Yellow
Gray
Blue
Reader Ctrl
RX
TX
GND
+ 12V
9
8
32
33
30
31
29
Yellow
GND
+ 12V
37
38
35
36
34
Reader Ctrl
Black
Red
1
2
A B C
D E F
3
G H I
4
J K L
5
6
M N O
7
PQRS
T U V
WXYZ
*
0
#
9
8
Reader_Data0
Reader_Data1
Brown
Green
24
25
26
27
28
29
30
31
32
33