TCP/IP Network Access Controller
34
4.6.2.2
Direction
In the “Reader Setting” menu, select “Set SYS Reader” menu item and press “#” to enter its
interface. Select “Direction” menu item, press “#” to enter the interface below. The LCD will
display the status of the direction. Press “#” to toggle between Entry and Exit status. Press
“*” to exit and the setting will take effect.
4.6.3
Set AUS Reader
The settings for AUS reader are similar to the SYS reader except the Keypad setting. In the
“Reader Setting” menu, select “Set AUS Reader” menu item and press “#” to enter its
interface.
Note that the AUS reader only supports Wiegand format. There is only Wiegand signal input,
no Wiegand signal output.
The setup procedures of Timeout Time and Direction of AUS reader are the same with SYS
reader. To enable / disable the Keypad function of the AUX reader, press “#” to toggle
between disabled and enabled. Press “*” to exit and the setting will take effect.
4.7
Door Setting
EFC301F controls a single door. The user can set the door open time, door over time and
door open mode.
In the “System Setting” main menu, scroll to the “Door Setting” menu item and press “#” to
enter the “Door Setting” submenu. Scroll to select different menu items.
AUX Reader Keypad:
enabled
[
#
]
to toggle
AUX Reader Keypad:
disabled
[
#
]
to toggle
Timeout Time
Direction
Keypad Setting
Set SYS Reader
Set AUS Reader
Direction
Exit
[
#
]
to toggle
Direction
Entry
[
#
]
to toggle