55
3.10 Control Setup Menu
Diagram 3.18
Diagram 3.18 is a screen shot of the Control Setting Menu. This menu is to define the settings for
DVR remote control through serial interface in the RS232/RS485 menu. The following fields are
defined in the Control Setting Menu:
RS232:
1. RS232 Baud Rate
This field is to set the speed at which is used to transmit instruction or information through the
RS232 port on the DVR. There are six different speeds, 2400 BPS, 4800 BPS, 9600 BPS, 19200
BPS, 38400 BPS and 57600 BPS. The default setting from the factory is 9600 BPS. To change
this, simply use the Jog Dial on the DVR.
2. RS232 Stop Bit
This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2.
The default in the DVR is set to 1. To change this, simply use the Jog Dial on the DVR.
3. RS232 Parity
This field is to select the parity level at which you will be connected. You can choose between
None, Odd, or Even parity levels. Default is set to none. To change this, simply use the Jog Dial
on the DVR.