13.2
List of alarms
The table below lists all the possible alarms. The alarms highlighted in grey do not occur when proofing is configured (E12 = 0).
Alarm
Meaning
HIGH EVAPORATOR TEMPERATURE
To correct:
-
check the evaporator temperature
-
check the value of parameters A1 and A2
Main results:
-
all loads are deactivated
HIGH CABINET TEMPERATURE
To correct:
-
check the cabinet temperature
-
check the value of parameters A3 and A4
Main results:
-
all the loads are deactivated until the alarm stops
-
the word alarm will disappear only when that area is pressed
DOOR OPEN
To correct:
-
check the condition of the door
-
check the value of parameters i0, i1 and i2
Main results:
-
the effect set by parameter i0
HIGH PRESSURE
To correct:
-
check the state of the high pressure input
-
check the value of the parameters relating to the multi-purpose input
configured as high pressure
Main results:
-
the compressor and evaporator fan are switched off, the condenser fan
remains on
LOW PRESSURE
To correct:
-
check the state of the low pressure input
-
check the value of the parameters relating to the multi-purpose input
configured as low pressure
Main results:
-
the compressor and condenser fan are switched off
COMPRESSOR THERMAL SWITCH
To correct:
-
check the state of the compressor thermal switch input
-
check the value of the parameters relating to the multi-purpose input
configured as compressor thermal switch
Main results:
-
the compressor is switched off
COMPRESSOR MAINTENANCE
To correct:
-
reset the counter of the compressor operation days
Main results:
-
none; this is only a visual alarm and has no effect on regulation
THERMAL SWITCH
To correct:
-
check the state of the thermal switch input
-
check the value of the parameters relating to the multi-purpose input
configured as thermal switch
Main results:
-
all loads are deactivated
EVAPORATOR FAN THERMAL
SWITCH ALARM
To correct:
-
check the condition of the multi-purpose input configured as the evaporator
fan thermal switch alarm
Main results: