BAKING DELAY phase (optional: phase 5 retarding-proofing; phase 3 proofing)
Retarding-proofing:
Proofing:
Depending on the needs of the user, the baking delay phase can be disabled (the cycle is automatically interrupted at the end of the
proofing phase) or enabled with a predefined time (the cycle is automatically interrupted at the end of the counter) or an infinite
duration by the end user (the cycle is automatically interrupted by holding down the STOP key). This may be done when setting the
cycle and with the cycle in progress.
Temperature regulation is active and has a neutral zone adjustment, the working setpoint is set by the end user.
Relative humidity regulation is active and has a neutral zone adjustment, the working setpoint and evaporator fan speed are set by the
end user.
At the end of the proofing phase (if the baking delay phase is not enabled) or at the end of the baking delay phase of every cycle, the
buzzer will sound (if parameter E1 is configured) and/or the message “CYCLE COMPLETED” will appear (if parameter E2 is configured).