07. INSTALLATION INSTRUCTIONS
16
Follow the instructions below before installing your stove.
Select the position where the stove is to be installed and:
•
Arrange the connection to the vent pipe for fume extraction
•
Arrange the external air intake (combustion air)
•
Arrange the connection to the earthed mains
•
The electical system of the room where the stove is to be installed must be earthed, otherwise the control board may not
work properly.
•
Place the stove on the floor in a convenient position for the connection to the vent pipe and close to the combustion air
intake.
•
The appliance must be installed on a floor with an adequate loading-bearing capacity.
•
Should the existing floor not comply with the requirement above, proper measures must be taken (for instance, the
installation of a load distribution plate).
•
All the structures which can catch fire if exposed to excessive heat must be protected. Floors made from wood or
inflammable materials must be protected using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
•
The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
•
This appliance is not suitable to be installed on a shared vent pipe.
•
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must
be positioned at the same height of the pipe located on the stove back. Exhaust fume pipes must be suitable for pellet
stoves and therefore made from coated steel or stainless steel, with a diameter of 8cm and fitted with adequate gaskets.
•
The combustion air intake (Φ 80mm) must be connected directly to the outside or to adjacent rooms provided they are fitted
with external air supply vents (Φ 80mm) and are not used as bedrooms or bathrooms or, whenever a fire hazard exists, as
storage rooms, garages, combustible material warehouses, etc. The air vents must be placed in such a way that they cannot be
clogged either from the outside or inside and must be protected using a grille, a metal mesh or other suitable means provided
they do not reduce the minimum section.
•
If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood cladding, etc.),
the following minimum clearances must be complied with:
“See stove data plate”.
•
During installation, the installer must also take into consideration the
convective air sections
: the structure housing the
appliance must be fitted with ventilation slots.
A = 740 cm²
B = 366 cm²
Summary of Contents for MAJOLICA LINE
Page 1: ...PELLET STOVES INSTRUCTION MANUAL MAJOLICA LINE SLIM LINE EN PELLET LINE...
Page 3: ...2...
Page 13: ...03 CANNA FUMARIA 12 EXISTING VENT PIPE TRADITIONAL EXTERNAL VENT PIPE...
Page 22: ...21 07 INSTALLATION INSTRUCTIONS...
Page 24: ...07 INSTALLATION INSTRUCTIONS 23...
Page 25: ...08 DATA PLACES 24...
Page 26: ...08 DATA PLACES 25...
Page 27: ...08 DATA PLACES 26...
Page 62: ...61 11 N100 MICRONOVA ELECTRONICS WITH 3 BUTTON LED DISPLAY 11 5 Connections...
Page 70: ...69 12 N100 MICRONOVA ELECTRONICS WITH 6 BUTTON LED DISPLAY 12 5 Connections...
Page 88: ...87...