06. STOVE EFFIENCY
15
Highly efficient stoves may pose difficulties for fume extraction.
In order for a vent pipe to work properly its internal temperature must increase as a consequence of the fumes generated during
combustion.
The stove efficiency instead depends on its capacity to deliver most of the generated heat to the surrounding environment. As a
consequence the more efficient the stove, the colder the combustion exhaust fumes, resulting in a reduced draught.
A traditional chimney flue, with a rough design and insulation, is more efficient if used with a traditional open fireplace or a poor
quality stove where most of the heat is lost with the fumes.
Therefore, purchasing a quality stove often entails modifying the existing chimney flue to obtain a better insulation, even when it
already works properly with old appliances.
Poor draught results in the stove not operating when hot or in smoke spillage.
•
Connecting the stove pipe to an existing chimney flue that has already been used with an old appliance is a common mistake.
In this way two solid-fuel appliances share the same chimney flue, which is wrong and dangerous.
•
If the two appliances are used simultaneously, the fume load might exceed the existing chimney flue capacity resulting in
downdraught. If only one appliance is used, the fume heat will facilitate draught but the cold air coming from the other
appliance not in use will cool down exhaust fume temperature again blocking the draught.
•
Besides the problems described so far, if the two appliances are placed on different levels the communicating vessel
principle might be interfered with, causing combustion fumes to be drawn in an irregular and unforeseeable way.
Summary of Contents for MAJOLICA LINE
Page 1: ...PELLET STOVES INSTRUCTION MANUAL MAJOLICA LINE SLIM LINE EN PELLET LINE...
Page 3: ...2...
Page 13: ...03 CANNA FUMARIA 12 EXISTING VENT PIPE TRADITIONAL EXTERNAL VENT PIPE...
Page 22: ...21 07 INSTALLATION INSTRUCTIONS...
Page 24: ...07 INSTALLATION INSTRUCTIONS 23...
Page 25: ...08 DATA PLACES 24...
Page 26: ...08 DATA PLACES 25...
Page 27: ...08 DATA PLACES 26...
Page 62: ...61 11 N100 MICRONOVA ELECTRONICS WITH 3 BUTTON LED DISPLAY 11 5 Connections...
Page 70: ...69 12 N100 MICRONOVA ELECTRONICS WITH 6 BUTTON LED DISPLAY 12 5 Connections...
Page 88: ...87...