Case
Case
Case
Case
Case:
ABS grey (RAL 7043); self-extinguishing
degree: V-0 according to UL 94.
Front protection
Front protection
Front protection
Front protection
Front protection - designed and tested for
IP 65(*) and NEMA 4X for indoor locations (when
panel gasket is installed).
(*)
Tests were performed in accordance with CEI
70-1 and NEMA 250-1991.
Installation
Installation
Installation
Installation
Installation: panel mounting
Rear terminal block
Rear terminal block
Rear terminal block
Rear terminal block
Rear terminal block:15 screw terminals (screw
M3, for cables from
φ
0.25 to
φ
2.5 mm
2
or from
AWG 22 to AWG 14 ) with connection diagrams
and safety terminal block cover.
Dimensions:
Dimensions:
Dimensions:
Dimensions:
Dimensions: according to DIN43700 48 x 48 mm,
depth 105 mm.
Weight:
Weight:
Weight:
Weight:
Weight: 200 g max.
Power supply
Power supply
Power supply
Power supply
Power supply:
- 100V to 240V AC 50/60Hz (-15% to + 10% of
the nominal value).
- 24 V AC/DC (+ 10 % of the nominal value).
Power consumption
Power consumption
Power consumption
Power consumption
Power consumption: 9 VA max / 4 W.
Insulation voltage
nsulation voltage
nsulation voltage
nsulation voltage
nsulation voltage: 2300 V rms according to
EN 61010-1.
Display updating time
Display updating time
Display updating time
Display updating time
Display updating time: 500 ms.
Sampling time:
Sampling time:
Sampling time:
Sampling time:
Sampling time: 500 ms.
Resolution
Resolution
Resolution
Resolution
Resolution: 30000 counts.
Precision:
Precision:
Precision:
Precision:
Precision: + 0.3% v.f.s. + 1 digit @ 25°C of
room temperature.
Common mode rejection
Common mode rejection
Common mode rejection
Common mode rejection
Common mode rejection: 120 dB at 50/60
Hz.
Normal mode rejection:
Normal mode rejection:
Normal mode rejection:
Normal mode rejection:
Normal mode rejection: 60 dB at 50/60 Hz.
Electromagnetic compatibility and
Electromagnetic compatibility and
Electromagnetic compatibility and
Electromagnetic compatibility and
Electromagnetic compatibility and
safety requirements
safety requirements
safety requirements
safety requirements
safety requirements: This instrument con-
forms the directives EEC 89/336 (reference har-
monized standard CEI EN-61326
Emission requirements:
Calss A for 24 V AC/DC power supply (residential
environment).
Class B – for 100/240V AC power supply (indus-
trial environment).
This instrument also conforms to directives 73/23/
EEC and 93/68/EEC (reference harmonized
standard EN 61010-1).
Installation category
Installation category
Installation category
Installation category
Installation category: II
Pollution category
Pollution category
Pollution category
Pollution category
Pollution category: 2
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift:
Temperature drift:
< 200 ppm/°C (RJ excluded) for TC type L, J, K
and N.
< 400 ppm/°C for RTD input and input from
thermocouple T.
< 800 ppm/°C for RTD input with 1/10°C resolution
(model 0316).
< 500 ppm/°C for RTD input with 1/10°C resolution
(model 0216).
Operating temperature:
Operating temperature:
Operating temperature:
Operating temperature:
Operating temperature: from 0 to 50°C (from 32
to 122°F).
Storage temperature:
Storage temperature:
Storage temperature:
Storage temperature:
Storage temperature: -30 to +70°C (-22 to
158°F)
Humidity
Humidity
Humidity
Humidity
Humidity: from 20 % to 85% RH, non condensing.
Protections
Protections
Protections
Protections
Protections:
1) WATCH DOG (hardware/software) for the
automatic restart.