2
GB
GB
GB
GB
GB
MEASURING INPUTS
MEASURING INPUTS
MEASURING INPUTS
MEASURING INPUTS
MEASURING INPUTS
NOTE
NOTE
NOTE
NOTE
NOTE: Any external components (like zener
barriers etc.) connected between sensor and input
terminals may cause errors in measurement due
to excessive and/or not balanced line resistance or
possible leakage currents.
TC INPUT
TC INPUT
TC INPUT
TC INPUT
TC INPUT
Fig. 3 THERMOCOUPLE CONNECTION
NOTES
NOTES
NOTES
NOTES
NOTES:
1) Do not run input wires together with power line
cables.
2) For TC wiring use proper compensating cable
preferably shielded.
3) When a shielded cable is used, it should be
connected at one point only.
2.
2.
2.
2.
2. ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
Connections are to be made with the instrument
housing installed in its proper location.
Fig. 2 REAR TERMINAL BLOCK
10
9
+
_
10
9
+
_
Shield
Shield
+
-
02-0316-1-DER.pmd
22/04/2004, 16.19
2