<07##
$SSHQGLFHV
953#
9HFWRU
#
'ULYH
#0#
+$
7968;7
$33(1',;
#
%
#0#953#
00,
#
/,67,1*
VECTOR DRIVE
RELEASE 4.8
4.0 kW 380-460v
..MENU LEVEL
....DIAGNOSTICS
......TOTAL SPD.DMD. [6] = 0.00 %
h.....SPEED FB UNFIL [7] = 0.00 %
......SPEED FEEDBACK [11] = 0.00 %
......SPEED ERROR [8] = 0.00 %
......TORQUE DEMAND [9] = 0.00 %
......TORQUE FEEDBACK [10] = 0.00 %
......CURRENT FEEDBACK [78] = 0.00 %
f.....TERMINAL VOLTS [480] = 0 VOLTS
f.....DC LINK VOLTS [613] = 608 VOLTS
h.....DC VOLTS UNFLT [684] = 608 VOLTS
f.....TERM V INTEGRAL [623] = 100.00 %
......ACTUAL POS I LIM [13] = 100.00 %
......ACTUAL NEG I LIM [14] = -100.00 %
......INVERSE TIME O/P [15] = 100.00 %
......AT CURRENT LIMIT [16] = FALSE
......AT ZERO SPEED [17] = TRUE
......AT ZERO SETPOINT [18] = TRUE
......AT STANDSTILL [19] = TRUE
......STALL TRIP [20] = OK
......RAMPING [21] = FALSE
......DRIVE START [23] = FALSE
......DRIVE ENABLE [24] = FALSE
......OPERATING MODE [25] = STOPPED
......HEALTHY [27] = TRUE
......HEALTH OUTPUT [12] = TRUE
......READY [559] = FALSE
......RUN [28] = FALSE
......ANIN 1 (C3) [29] = 0.000 VOLTS
......ANIN 3 (F2) [31] = 0.000 VOLTS
......ANIN 4 (F3) [32] = 0.000 VOLTS
......ANIN 5 (F4) [33] = 0.000 VOLTS
......ANOUT 1 (C5) [34] = 0.000 VOLTS
......ANOUT 2 (F5) [35] = 0.000 VOLTS
......COAST STOP [26] = FALSE
......PROGRAM STOP [22] = FALSE
......DIGIN B6 JOG [37] = FALSE
......DIGIN B7 START [36] = FALSE
......DIGIN B8 ENABLE [38] = FALSE
......DIGIN 1 (E2) [39] = FALSE
......DIGIN 2 (E3) [40] = FALSE
......DIGIN 3 (E4) [41] = FALSE
......DIGIN 4 (E5) [521] = FALSE
......DIGOUT 1 (E6) [42] = TRUE
......DIGOUT 2 (E7) [43] = TRUE
......DIGOUT 3 (E8) [44] = FALSE
......RAISE/LOWER O/P [45] = 0.00 %
......SPT SUM O/P 1 [46] = 0.00 %
......SPT SUM O/P 2 [385] = 0.00 %
......SPT SUM O/P 3 [386] = 0.00 %
......RAMP OUTPUT [47] = 0.00 %
......PRESET O/P [110] = 0.00 %
......SPEED SETPOINT [48] = 0.00 %
f.....SEQ RUN INPUT [49] = 0.00 %
f.....SEQ OUTPUT [50] = 0.00 %
......ENCODER [51] = 0 RPM
....SETUP PARAMETERS
......RAMPS
........RAMP ACCEL TIME [54] = 10.0 SECS
........RAMP DECEL TIME [55] = 10.0 SECS
f.......RAMP QUENCH [56] = FALSE
........RAMP HOLD [57] = FALSE <- [281]
........RAMP INPUT [58] = 0.00 % <- [345]
........% S-RAMP [59] = 0.00 %
........RAMPING THRESH. [60] = 1.00 %
........AUTO RESET [61] = TRUE
........EXTERNAL RESET [62] = FALSE
........RESET VALUE [63] = 0.00 %
........RAMPING [21] = FALSE
........RAMP OUTPUT [47] = 0.00 %
......OP-STATION
........SET UP
..........SETPOINT [507] = 0.0 %
..........LOCAL KEY ENABLE [632] = TRUE
........START UP VALUES
..........SETPOINT [503] = 0.0 %
..........REV DIRECTION [504] = FALSE
..........PROGRAM [505] = FALSE
..........LOCAL [506] = FALSE
........LOCAL RAMP
..........RAMP ACCEL TIME [511] = 10.0 SECS
..........RAMP DECEL TIME [512] = 10.0 SECS
..........% S-RAMP [516] = 0.00 %
h.........RAMP OUTPUT [509] = 0.00 %
......AUX I/O
........AUX START [66] = TRUE
........START [70] = FALSE <- [450]
........AUX JOG [67] = TRUE
........JOG INPUT [71] = FALSE <- [451]
........AUX ENABLE [68] = TRUE
........ENABLE [72] = FALSE <- [452]
f.......REM.SEQ.ENABLE [791] = FALSE
f.......REMOTE SEQ [786] = 0x0000
f.......SEQ STATUS [787] = 0x0C04
......JOG
........JOG SPEED 1 [75] = 10.00 %
........JOG SPEED 2 [76] = -10.00 %
........MODE [80] = FALSE
........JOG ACCEL RATE [113] = 10.0 SECS
........JOG DECEL RATE [114] = 10.0 SECS
......RAISE/LOWER
........RESET VALUE [82] = 0.00 %
........RAMP RATE [83] = 60.0 SECS
........RAISE INPUT [85] = FALSE
........LOWER INPUT [86] = FALSE
........MIN VALUE [87] = -100.00 %
........MAX VALUE [88] = 100.00 %
........EXTERNAL RESET [89] = FALSE
........RAISE/LOWER O/P [45] = 0.00 %
h.......RAISE/LOWER INIT [678] = 0.00 %
h.....INVERSE TIME
h.......AIMING POINT [116] = 105.00 %
h.......DELAY [117] = 60.0 SECS
h.......DOWN RATE [118] = 10.0 SECS
h.......UP RATE [148] = 120.0 SECS
h.......INVERSE TIME O/P [15] = 31.44 %
......STOP RATES
........RUN STOP TIME [120] = 10.0 SECS
........RUN STOP LIMIT [121] = 60.0 SECS
........FAST STOP TIME [123] = 1.0 SECS
........FAST STOP LIMIT [124] = 60.0 SECS
........USE SYSTEM RAMP [125] = TRUE
f.......PRE-START DELAY [122] = 0.500 SECS
f.......READY DELAY [352] = 0.000 SECS
........CONTACTOR DELAY [112] = 0.5 SECS
........PILOT 590 MODE [777] = FALSE
........STOP ZERO SPEED [126] = 1.00 %
........PROG STOP I-LIM [622] = 150.00 %
........COAST STOP [26] = FALSE
........PROGRAM STOP [22] = FALSE
......ALARMS / SEQ
........EXTERNAL TRIP [144] = FALSE
f.......REMOTE INHIBIT [788] = FALSE
f.......REMOTE DELAY [790] = 1.00
........REMOTE TRIP [789] = OK
h.......MOTOR TMP.TRIP [128] = 75.00 %
h.......MOTOR TMP.RST. [309] = 50.00 %
........MOTR.TMP.INHIBIT [146] = FALSE
h.......HEATSINK LEVEL [129] = 17.00 %
f.......ACK ALARM [166] = TRUE
........STALL INHIBIT [143] = FALSE
........STALL TORQUE [136] = 95.00 %
........STALL SPEED [138] = 4.00 %
........STALL DELAY [137] = 10.00
........STALL TRIP [20] = OK
........OVER SPD INHIBIT [145] = FALSE
........OVER SPEED LEVEL [139] = 120.00 %
h.......UNDER V LEVEL [685] = 440 VOLTS
h......./UNDER VOLTS [686] = TRUE
........5703 RCV.INHIBIT [142] = FALSE
f.......SPD.FBK.DELAY [687] = 10.000 SECS
f.......SPD.FBK.THRESHD [688] = 10.00 %
........SPD.FBK.INHIBIT [689] = FALSE
h.......HEALTH INHIBIT [219] = 0x0000
f.......OPERATING MODE [25] = STOPPED
f.......DRIVE START [23] = FALSE
f.......DRIVE ENABLE [24] = FALSE
f.......READY [559] = FALSE
f.......RUN [28] = FALSE
f.......HEALTH STORE [203] = 0x0000
f.......HEALTH WORD [217] = 0x0010
f.......FIRST ALARM [218] = 0x0010
f.......HEALTHY [27] = TRUE
f.......HEALTH OUTPUT [12] = TRUE
......CALIBRATION
........ENCODER LINES [131] = 2048
........ENCODER SUPPLY [774] = 50 %
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]