Rev. 009
ETL3100
CMD EXCITBON
CMD EXCITBON
CMD EXCITBON
CMD EXCITBON
Enables R.F. output of Exciter B (Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
CMD EXCITBOFF
CMD EXCITBOFF
CMD EXCITBOFF
CMD EXCITBOFF
Disables R.F. output of Exciter B (Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
CMD EXCITERAPREF
CMD EXCITERAPREF
CMD EXCITERAPREF
CMD EXCITERAPREF
Sets Exciter A as preferential exciter (Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
CMD EXCITERBPREF
CMD EXCITERBPREF
CMD EXCITERBPREF
CMD EXCITERBPREF
Sets Exciter B as preferential exciter (Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
(Only for dual drive system)
To set the information returned with the CMD STATUS it is possible to enable/disable the desired item as
follows:
→
→
→
MAIN MENU GSM MENU GSM Stat.Mask Temperature: Enabled
Enabled
Enabled
Enabled
→
→
→
MAIN MENU GSM MENU GSM Stat.Mask Temperature: Disabled
Disabled
Disabled
Disabled
All items are initially enabled as default configuration.
The list of the events and alarm status reported by GSM module is as follows:
EVENTS
EVENTS
EVENTS
EVENTS
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
POWER IS UP
POWER IS UP
POWER IS UP
POWER IS UP
Shows the mains presence
POWER IS DOWN
POWER IS DOWN
POWER IS DOWN
POWER IS DOWN
Shows the lack in mains presence
-3dB ALARM IS UP
-3dB ALARM IS UP
-3dB ALARM IS UP
-3dB ALARM IS UP
Shows -3dB alarm presence, R.F. output is lower than -3dB threshold
-3dB ALARM IS DOWN
-3dB ALARM IS DOWN
-3dB ALARM IS DOWN
-3dB ALARM IS DOWN
Restoring from -3dB alarm
VSWR ALARM IS UP
VSWR ALARM IS UP
VSWR ALARM IS UP
VSWR ALARM IS UP
Shows VSWR alarm presence, reflected R.F. output is above the threshold set
VSWR ALARM IS
VSWR ALARM IS
VSWR ALARM IS
VSWR ALARM IS
DOWN
DOWN
DOWN
DOWN
Restoring from VSWR alarm
EXCITER TEMPERATURE
EXCITER TEMPERATURE
EXCITER TEMPERATURE
EXCITER TEMPERATURE
IS UP
IS UP
IS UP
IS UP
Shows a temperature alarm presence in the exciter module, temperature is above
the threshold value set
EXCITER TEMPERATURE
EXCITER TEMPERATURE
EXCITER TEMPERATURE
EXCITER TEMPERATURE
IS DOWN
IS DOWN
IS DOWN
IS DOWN
Restoring from Exciter Temperature alarm
AMPLIFIER
AMPLIFIER
AMPLIFIER
AMPLIFIER
TEMPERATURE IS UP
TEMPERATURE IS UP
TEMPERATURE IS UP
TEMPERATURE IS UP
Shows a temperature alarm presence in an amplifier module, temperature is above
the threshold value set
AMPLIFIER
AMPLIFIER
AMPLIFIER
AMPLIFIER
TEMPERATURE IS
TEMPERATURE IS
TEMPERATURE IS
TEMPERATURE IS
DOWN
DOWN
DOWN
DOWN
Restoring from Amplifier Temperature alarm
SUPERVISOR
SUPERVISOR
SUPERVISOR
SUPERVISOR
TEMPERATURE IS UP
TEMPERATURE IS UP
TEMPERATURE IS UP
TEMPERATURE IS UP
Shows a temperature alarm presence in supervisor module, temperature is above
the threshold value set
SUPERVISOR
SUPERVISOR
SUPERVISOR
SUPERVISOR
TEMPERATURE IS
TEMPERATURE IS
TEMPERATURE IS
TEMPERATURE IS
DOWN
DOWN
DOWN
DOWN
Restoring from Supervisor Temperature alarm
MODULATION ALARM
MODULATION ALARM
MODULATION ALARM
MODULATION ALARM Shows a modulation alarm presence, no modulation inputs are available
Gen 2014
CMAN3100
Page 77
77
77
77