SigNET 200/300 User Guide  

 12  

 

  ELAB 1543 

 
 

4.8 

Changing a User Code 

If users have the right to change their user code, this can be done through the 
Keypad.  

Note, if the system is set for 5-digit user codes, a new 5-digit code must be entered. 
The system will not accept a code with fewer numbers than it is set to receive. 

To change a user code:  
1.  Scroll to CHANGE CODE and press SELECT (right soft key).  

A randomly generated user code appears.  

2.  Select new code, if acceptable. Or overwrite by entering the new user code and 

press ENTER (right soft key). 

3.  Confirm the new code, press SAVE (right soft key).  
4.  Press BACK (left soft key) to return to the previous screen to amend the code.  
During the process if the display times out, the old code remains valid. 

4.9 Using 

SMS 

SigNET systems with modems and appropriate configuration, allow SMS 
messaging. To use SMS, each user must have the appropriate user profile 
rights. Notification of the following events can be sent to users as SMS 
messages: 
• Alarm 

Activation 

• Confirmed 

Alarms 

• 

Fault and Tamper  

• 

Arming and Disarming (Mode Change) 

• 

Inhibit and Isolate 

• 

All other types of events 

4.9.1 SMS Events 

To receive Event notifications, SMS setup must have the phone number; the 
number must be enabled for SMS; and the Events must be toggled for SMS 
Event notification. 

Add the phone number for SMS use: 

1.  Scroll to the SMS EVENTS option and press SELECT. The following 

configuration options are available: 

2.  Add by providing phone number for receipt of event notification 

(Requires three-digit country code prefix)  
Edit phone number as needed. (Within this level is also enabling SMS 
and selecting Reported Events.) Delete: Remove phone number as 
needed 

3.  Press BACK to exit the SMS EVENTS menu.  

Each user may set a maximum of five phone numbers for SMS receipt. 

 
 

 

 

Note 

Where User Duress feature is enabled, consecutive user codes (i.e. 2906, 2907) are not 
permitted, as entering this code from the Keypad would activate a user duress event.  

…CHANGE CODE… 
EXIT  

 

SELECT 

CODE   4740 
BACK   SELECT 

…SMS EVENTS… 
EXIT  

 

SELECT 

…ADD… 
EXIT  

 

SELECT 

SMS NUMBER 
 

 

 

353    
BACK   ENTER 

UPDATED 

UPDATED 
 

 

 

Summary of Contents for SigNET200 Series

Page 1: ...E L A B1 5 4 3 S i g N E T2 0 0 3 0 0S e r i e s U s e r G u i d e...

Page 2: ...en changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technologies...

Page 3: ...THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 CODED RESTORE 8 3 9 USING 868MHZ WIRELESS FOB 8 3 10 USING A PORTABLE ACE 8 3 11 USING X10 FEATURES 9 4 USER MENU OPTIONS 10 4 1 INHIBITING A...

Page 4: ...NET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators LE...

Page 5: ...e down arrow key moves the user to the next programming option in the same menu level Continually press this key to scroll through all programming options available on the current menu level In alphan...

Page 6: ...buzzer sounds to indicate that the user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set...

Page 7: ...on the Keypad and the Alert LED flashes The Keypad continues to display the alert until the alert is restored 3 7 Restoring an Alarm Activation Alert Alert conditions on the SigNET are indicated on t...

Page 8: ...digit reset code displays on the top line 4 Provide 6 digit code to installer ARC 5 Receive newly generated code from installer ARC 6 Enter new code at the AUTH CODE prompt 7 Press SELECT The message...

Page 9: ...a hall light could be configured to turn on when the front door of the house is opened Alternatively the function can be controlled directly at the Keypad X10 settings are programmed by the installati...

Page 10: ...l to the ISOLATE option and press SELECT right soft key 2 Scroll to the ZONES option and press SELECT right soft key 3 A list of zones on the system displays Select the required zone and toggle the se...

Page 11: ...Chime Function The chime function can be enabled or disabled on all zones where the chime has been programmed as an audible alert feature To enable or disable the chime function 1 Scroll to the CHIME...

Page 12: ...ts can be sent to users as SMS messages Alarm Activation Confirmed Alarms Fault and Tamper Arming and Disarming Mode Change Inhibit and Isolate All other types of events 4 9 1 SMS Events To receive Ev...

Page 13: ...Depending on the SMS authentication configured by the installation engineer the user s mode of SMS may vary If the system SMS Authentication is set to the SMS PIN Code or Caller ID it is necessary to...

Page 14: ...code followed by either a space or a full stop Where is the code and command is the command command or command For example the command HELP is this text HELP or HELP Table 3 COMMANDS code Using Code U...

Page 15: ...engineer access 1 Scroll to the GRANT ACCESS option and press SELECT right soft key 2 Select the ALLOW ENGINEER option right soft key and select ENABLED To disallow engineer manufacturer access follo...

Page 16: ...this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Manager The PARTSET B option applies protection t...

Page 17: ...e time and date information is accurate these fields are presented in the event log when reporting system events To set date or time see Section 4 3 TEST Standard Manager This menu option provides the...

Page 18: ...SigNET 200 300 User Guide 18 ELAB 1543 Appendix C Zone Chart Zone Description...

Reviews: