SigNET 200/300 User Guide  

 

 
16  

ELAB 

1543 

 

 

 

 

   

 

 

   

Appendix A: Standard User Settings 

The operational features of the SigNET 200/300 system are described below. The installation engineer informs 
users of their user rights assigned to each user profile. Depending on how the system has been programmed, users 
may have rights to all or some of these features.  

 

Operation 

User Profile 
Default 

Description 

FULLSET 

 

Limited 
Standard  
Manager 

The FULLSET operation fully sets the alarm system and provides full 
protection to a building (opening of any alarm zones activates the alarm).  
On selecting FULLSET, the buzzer sounds and the Keypad display 
counts down the exit time period. Exit the building before this time period 
has expired.  
When the exit time period has expired, the system is set and opening of 
entry/exit zones starts the entry timer. If the system is not Unset before 
the entry timer expires, the alarm is activated. 
To perform a FULLSET, see Section 3.1. 

PARTSET A 
 

 

Standard  
Manager 

The PARTSET A option provides perimeter protection to a building while 
allowing free movement through the exit and access areas.  
Zones that have been classified as 

EXCLUDE A

 remain unprotected in 

this mode. By default, there is no exit time; the system sets instantly on 
selection of this mode. An exit timer can be applied to this mode by 
enabling the Partset A timed variable. 
To perform a PARTSET A, see Section 3.2. 

PARTSET B 

 

 

Standard  
Manager 

The PARTSET B option applies protection to all zones except those that 
have been classified as 

EXCLUDE B

By default there is no exit time; the system sets instantly on selection of 
this mode. An exit timer can be applied to this mode by enabling the 
Partset B timed variable. 
To perform a PARTSET B, see Section3.3. 

FORCE SET 

 

Standard  
Manager 

The FORCESET option is presented on the Keypad display when an 
attempt is made to set the system while an alarm zone is faulty or still 
open (the top line of the display shows the open zone).  
Selecting this option sets the alarm and inhibits the zone for that set 
period.  
To perform a FORCESET, see Section 3.5. 

UNSET 

 

 

Limited 
Standard  
Manager 

The UNSET operation unsets the alarm. This menu option is only 
presented on the Keypad after an alarm has been activated and a valid 
user code has been entered. 
To UNSET the system, see Section 3.6. 

RESTORE 

 

Standard  
Manager 

The RESTORE operation restores an alert condition on the system and 
clears the alert message associated with that alert condition.  
An alert condition can only be restored after the zone(s) or fault(s) that 
triggered the alert condition have been restored to their normal operating 
state and the RESTORE option in user programming is selected for that 
zone.  
To RESTORE an alert, see Section 3.7. 

 

Summary of Contents for SigNET200 Series

Page 1: ...E L A B1 5 4 3 S i g N E T2 0 0 3 0 0S e r i e s U s e r G u i d e...

Page 2: ...en changing or installing expanders on the SigNET 200 300 system always ensure that all anti static precautions are adhered to while handling connectors wires terminals and PCBs Europlex Technologies...

Page 3: ...THE SYSTEM 7 3 7 RESTORING AN ALARM ACTIVATION ALERT 7 3 8 CODED RESTORE 8 3 9 USING 868MHZ WIRELESS FOB 8 3 10 USING A PORTABLE ACE 8 3 11 USING X10 FEATURES 9 4 USER MENU OPTIONS 10 4 1 INHIBITING A...

Page 4: ...NET Keypad may be factory fitted with a Portable ACE PACE proximity device reader and or a wireless module for the enrolment of wireless sensors Figure 1 SigNET Keypad Table 1 LED Status Indicators LE...

Page 5: ...e down arrow key moves the user to the next programming option in the same menu level Continually press this key to scroll through all programming options available on the current menu level In alphan...

Page 6: ...buzzer sounds to indicate that the user should exit the building When the system has been fully set the LCD displays FULLSET on the bottom line for approximately 10 seconds If the alarm fails to set...

Page 7: ...on the Keypad and the Alert LED flashes The Keypad continues to display the alert until the alert is restored 3 7 Restoring an Alarm Activation Alert Alert conditions on the SigNET are indicated on t...

Page 8: ...digit reset code displays on the top line 4 Provide 6 digit code to installer ARC 5 Receive newly generated code from installer ARC 6 Enter new code at the AUTH CODE prompt 7 Press SELECT The message...

Page 9: ...a hall light could be configured to turn on when the front door of the house is opened Alternatively the function can be controlled directly at the Keypad X10 settings are programmed by the installati...

Page 10: ...l to the ISOLATE option and press SELECT right soft key 2 Scroll to the ZONES option and press SELECT right soft key 3 A list of zones on the system displays Select the required zone and toggle the se...

Page 11: ...Chime Function The chime function can be enabled or disabled on all zones where the chime has been programmed as an audible alert feature To enable or disable the chime function 1 Scroll to the CHIME...

Page 12: ...ts can be sent to users as SMS messages Alarm Activation Confirmed Alarms Fault and Tamper Arming and Disarming Mode Change Inhibit and Isolate All other types of events 4 9 1 SMS Events To receive Ev...

Page 13: ...Depending on the SMS authentication configured by the installation engineer the user s mode of SMS may vary If the system SMS Authentication is set to the SMS PIN Code or Caller ID it is necessary to...

Page 14: ...code followed by either a space or a full stop Where is the code and command is the command command or command For example the command HELP is this text HELP or HELP Table 3 COMMANDS code Using Code U...

Page 15: ...engineer access 1 Scroll to the GRANT ACCESS option and press SELECT right soft key 2 Select the ALLOW ENGINEER option right soft key and select ENABLED To disallow engineer manufacturer access follo...

Page 16: ...this mode An exit timer can be applied to this mode by enabling the Partset A timed variable To perform a PARTSET A see Section 3 2 PARTSET B Standard Manager The PARTSET B option applies protection t...

Page 17: ...e time and date information is accurate these fields are presented in the event log when reporting system events To set date or time see Section 4 3 TEST Standard Manager This menu option provides the...

Page 18: ...SigNET 200 300 User Guide 18 ELAB 1543 Appendix C Zone Chart Zone Description...

Reviews: