Spaces and distances
It is essential to check the space where the stove will operate for an optimal operation.
-
The volume of the house or the working space mustn’t be smaller than 40m³.
-
There has to be a permanent opening of airflow to the outside of the place of the installation,
minimum 800 cm², not obstruable and protected with a permanent grill, or the stove has to be
connected to the outside by an air intake tube (as shown below), do not exceed 80 cm in length
with 2 curves maximum.
-
The air can be taken by the rooms contiguous to the room where the stove has been installed on
condition that there are air intakes, not located in the bedroom, bathroom or where there are
flammable materials.
-
If the stove is installed in a room with
wooden or flammable floor, you must
protect the floor by using (in addition
to the anti-vibration feet provided)
also an insulating slab, protruding at
least 20 cm on the side and 40 cm on
the front.
-
In the space where the stove is placed, it is compulsory the presence of a suitable fumes
evacuation system
-
It is not compulsory to connect the air intake tube of the stove directly outside (see picture) but it
is recommended for a better efficiency (energy-saving). In any case, it is necessary to ensure at
least 50 m³/h of air. Grill 800 cm².
-
The electrical system must be in accordance with the law; check the efficiency of the earthing
circuit. The supply line must be of an appropriate section to the power of the device.
-
When you place the stove in a room you must
check that the walls are not flammable and that
flammable materials such as curtains,
wallpaper, etc. have not been applied on the
walls. You must place the stove at a distance
not less than 20 cm laterally and not less than
10 cm at the back. If there is an internal flue it’s
advisable to keep a distance of 10 cm between
the flue and the wall.
-
Do not place flammable materials at a distance
less than 1 meter from the stove.
-
We also recommend to keep out of the thermal
radiation area, anyway at a distance of at least
1 m from the warming block, all types of
combustible or flammable materials such as:
trusses, wooden fittings, curtains, flammable
liquids.