![Euroalpi Pasubio Use And Maintenance Manual Download Page 20](http://html1.mh-extra.com/html/euroalpi/pasubio/pasubio_use-and-maintenance-manual_2437041020.webp)
20
10.8 Stand-by
If enabled in the menu, standby function allows to turn off the stove once the conditions explained below
are respected. It is enabled if, at a given time by the parameter PR44, the room temperature is higher than
the set temperature (Set environment) plus the parameter PR43. The display shows " STANDBY " and the
minutes left. (
Figure 10
).
Figure 10
At the end of the time given by the parameter PR44, the display shows the message "WAIT COOLING". In
this state, the stove has turned off the auger (auger LED off), the exchanger switches off when it reaches
the threshold given by the parameter PR15 and the LED ON \ OFF flashes. (
Figure 10a
)
.
Figure 10a
When the fumes temperature reaches the threshold given by the parameter PR13, the stove goes into
stand-by mode and "WAIT COOLING-" passes on the display. The auger is off (auger LED off), the
exchanger is off (exchanger LED off), as well as the smoke extractor. (
Figure 10b).
Figure 10b
If the room temperature drops below the set temperature (Set environment) minus the threshold given by
the parameter PR43, the stove will switch on again.