![Euroalpi Pasubio Use And Maintenance Manual Download Page 17](http://html1.mh-extra.com/html/euroalpi/pasubio/pasubio_use-and-maintenance-manual_2437041017.webp)
17
Before switching on the stove, the display appears as shown in
Figure 2.
Figure 2
To turn on the stove, press on P4 for a few seconds. The successful ignition is indicated in the display with
the message "START" as in (
Figure 3
). This phase lasts for a time given by the parameter PR01. Under these
conditions, the stove will go in the state of preheating, the ignition turns on (shown by the ignition LED)
and so does the smoke extractor. Malfunctions during the ignition phase are shown on the display and the
stove goes into an alarm state.
(Refer to chapter 9).
Figure 3
10.2 Pellet loading
After about 1 minute, the pellet loading phase begins, the message "LOAD PELLET" passes on the display.
In a first phase the auger provides to load the pellets in the brazier for a time given by the parameter
PR40 (auger LED on), the speed of the fumes is defined by parameter PR42 and the ignition is always on
(ignition LED on). In the second phase, after the time of the parameter PR40 has passed, the auger turns
off (auger LED off) for a time given by the parameter PR41, while the speed of the fumes and the ignition
remain in the previous state. If the stove does not turn on after this phase, the auger turns on for a period
given by the parameter PR04, the fumes speed is given by the parameter PR16 and the ignition is on.
(
Figure 4
).
Figure 4
14:15
22.5°c P-2
OFF
14:15
22.5°c P-2
START
14:15
22.5°c P-2
LOAD
Pellet
Summary of Contents for Pasubio
Page 1: ...Use and maintenance manual for pellet stove...
Page 42: ...Below there is an example of installation of ducted stove in a home...
Page 43: ...17 Notes...