12.7 Safety thermal over-temperature alarm
It occurs when the general safety thermostat detects a temperature above the trigger threshold. The
thermostat intervenes and stops the auger and the controller intervenes indicating the alarm status (alarm
LED on) by displaying the
message
"Al
7
SAFETY
THERMAL " (
Figure 26
), and the
stove turns off.
Figure 26
Check that the thermal protection of the tank didn't activate, if
it has intervened please make sure that there are no
obstructions at the back and front openings of the stove or to
the air outlet grill, which block the right passage of air. Once
this is done, reset the safety thermostat, which is located in
the back of the stove (
Figure 27
), under the general switch,
covered by a plastic lid screwed on, remove the cap, press the
button, put the cap back; restart the stove and check if the
environment fan is working correctly. If the alarm persists, call
the
Authorized
Service
Provider.
Figure 27
12.8 Alarm absence depression
It occurs when the external pressure switch component detects a pressure/depression below the trigger
threshold. The pressure switch intervenes by turning the auger off, being these two electrically connected
in series, and the controller signals the alarm status (alarm LED on) displaying “AL 8
FAILURE DEPRESS”
on the display (
Figure 28
). The
stove turns off. Remove
voltage, clean carefully: the
brazier,
the
combustion
chamber, the passage of
smokes and the flue; if the
alarm
persists,
call
the
Authorized Service Provider.
Figure 28
12.9 Display message SERV
When the message "SERV"
appears, the stove has reached
1400 hours of operation. We
recommend that you call your
authorized service center for
routine maintenance.
(Figure 29)
Figure 29
Al7
SAFETY
THERMAL
Al8
FAILURE
DEPRESS
14:15
22.5°c P-2
Serv
Summary of Contents for Pasubio