12.3 Fumes temperature alarm
It occurs in the case the smokes probe detects a temperature higher than a set value fixed which can’t be
changed through parameter.
The display shows the message
"Al 3 HOT EXHAUST " as in
(
Figure 22
) and the stove goes
off. Electrically disconnect the
stove and call your authorized
service center.
Figure 22
12.4 Encoder smoke damaged alarm
It happens in case there is a damage in the fumes fan. The stove goes into alarm state and the message
"Al 4 FAN FAILURE " (
Figure 23
) will pass on the display. It occurs in the case in which the smoke extractor
is damaged or in the case the
fan speed of the smoke
extractor is not detected by the
board. In this case, reset the
alarm by pressing the On / Off
button
and
contact
an
authorized service center.
Figure 23
12.5 Firing failure alarm
It occurs when the ignition phase fails. That is what happens if the time given by the parameter PR01
passes without the fumes temperature overcomes the parameter PR13. The message "Al 5 NO LIGHTIN-
“ will pass on the display and
the stove goes into alarm state
(
figure 24
). Wait for the end of
the cooling cycle, clean the
brazier and proceed with a new
ignition.
Figure 24
12.6 Pellets absence Alarm
It occurs when, in working phase, the smokes temperature decreases below the parameter PR13. The
message "Al 6 NO PELLET" will pass on the display and the stove goes into alarm state (
Figure 25
)
.
Figure 25
Al3
HOT
EXHAUST
Al 4 ALAR AL 4 aspirat-guasto
Al4
FAN
FAILURE
Al6
NO
PELLET
Al5
NO
LIGHTIN-