10.3 Fire Present
After the fumes temperature has reached and overcome the value contained in the parameter PR13, the
system goes into power mode displaying "FLAME LIGHT" on the display. In this phase, it is checked that
the temperature remains stable for a predefined time given by parameter PR02. The fumes speed is given
by the parameter PR17, the auger will turn on for a time given by the parameter PR05 (auger LED on
intermittent) and the ignition is switched off (ignition LED off).
(Figure 5)
Any anomalies will stop the board
and this will report the error state. (Refer to chapter 9).
Figure 5
10.4 Stove on working mode
After the fumes temperature has reached and overcome the value contained in PR13 and maintained it for
at least a time PR02, the stove goes into working mode which is the normal operating. The display will
show the word "WORK". The power can be set by holding down the button P5 and P6 and the room
temperature can be set by pressing the button P1 and P2. (
Figure 6
). If the fumes temperature reaches the
threshold set by parameter
PR15, the air exchanger fan
lights on. (Led exchanger on).
Figure 6
During this phase, after a time given by the parameter PR03, the stove carries out a cleaning of the
brazier. The message "
CLEANING FIRE-POT " will pass on the display, the auger is turned on (auger LED
on) with a speed given by the parameter PR09, the smoke extractor speed given by parameter PR08.
(
Figure 6a
) Once the given time by the parameter PR12 has passed, the stove backs in working state.
Figure 6a
14:15
22.5°c P-2
Flame
light
14:15
22.5°c P-2
WORK
14:15
22.5°c P-2
CLEANING
FIRE - POT
Summary of Contents for Pasubio
Page 1: ...Use and maintenance manual for pellet stove...
Page 42: ...Below there is an example of installation of ducted stove in a home...
Page 43: ...17 Notes...
Page 44: ...44 Notes...