Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
34
(Translation of the original operating instructions) 2500234-01-08/18
16.2. System indications during setup, teach-in and normal operation
Operating mode
LED indicator
Door position
Position of the bolt tongue
Guard locking contr
ol
LM.FO_CL
(depending on setting also
LM.O.CL
)
Device diagnostics
status bit
LM.I_OD
Bolt position
status bit
LM.I_OT
Bolt position (SK)
safe input bit
LM.FI_SK
Status bit
LM.I_SK
Guard locking
status bit
LM.I_OL
Guard locking status (ÜK)
safe input bit
LM.FI_UK
Status bit
LM.I_UK
State
POWER (gn)
STATE (gn)
Lock (ye), only MGB2-L1/-L2
DIA (rd)
Normal operation
long OFF
shor
t ON
open
not
inser
ted
of
f
of
f
of
f
of
f
of
f
of
f
Normal operation, door open
long ON
shor
t OFF
closed
not
inser
ted
of
f
on
of
f
of
f
of
f
of
f
Normal operation, door closed
long ON
shor
t
OFF
closed
inser
ted
of
f
on
on
on
of
f
of
f
Normal operation, door closed, bolt tongue inser
ted
closed
inser
ted
on
on
on
on
on
on
Normal operation, door closed and locked
X
flashing quickly
X
not
inser
ted
on
of
f
of
f
of
f
of
f
of
f
Ready for guar
d locking, guar
d locking is active, bolt
tongue not inser
ted
Teach-in standby
(only for MGB2 unicode)
3 x
open
not
inser
ted
of
f
of
f
of
f
of
f
of
f
of
f
Door open; unit is r
eady for teach-in for another handle
module (only shor
t time after power-up)
Setup
(only for MGB2 unicode)
1 Hz
closed
inser
ted
on
on
on
of
f
on
of
f
Teach-in operation
alternately flash
-
ing
ST
ATE /DIA
X
X
of
f
of
f
of
f
of
f
of
f
Positive acknowledgment after completion of teach-in operation
Key to symbols
LED not illuminated
LED illuminated
10 Hz, 8 s
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes thr
ee times
X
Any state
Impor
tant
: If you do not find the displayed device status in the System status table, this indicates an internal device fault. In this case, you should contact the manufactur
er
.