9. Mounting
IMPORTANT
Ì
Mounting must be performed only by authorized personnel.
Ì
Depending on the substrate material, the detection range for the acquisition of the door position
may vary.
Ì
During mounting, pay attention to correct alignment. Use the alignment aids on the housing for the
interlocking/locking module and on the housing for the handle module (see
Figure 8)
.
With two-leaf hinged doors, one of the two door leaves must also be latched mechanically.
Use a rod latch (Item) or a double-door lock (Bosch Rexroth) for this purpose, for example.
For mounting steps , see
Figure 8
and
Figure 10
to
Figure 15
.
Attach system such that operation of the auxiliary release as well as inspection and maintenance are possible.
The locking screw must be screwed in and sealed again after mounting and after every use of the auxiliary release (original
set of seal labels order no. 155853). Tightening torque 0.5 Nm.
M6
T10
Figure 8:
Installation example for door hinged on the right (general view)