2500234-01-08/18 (Translation of the original operating instructions)
Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
EN
13. Electrical connection
All devices in a line of modules draw their power from a suitable bus module MBM. The connection is only allowed to be
made to a bus module MBM or an upstream module.
For detailed instructions on the connection of the overall system, please refer to the operating instructions for the bus
module MBM used.
CAUTION
Risk of damage to equipment or malfunctions as a result of incorrect connection.
Ì
Pay attention to the instructions on correct connection in the operating instructions for the bus
module MBM used.
13.1. Connecting modules
MGB2-Modular modules can either be connected together directly or using cables (see
Figure 17: Connecting modules
).
Each module has a top and a bottom connection. You can use either the bottom or the top connection or both if the module
is between two other modules.
The bottom module connector is already integrated. To use the top connection, change the connector's position. Only use
the module connector intended to connect modules together (see table below). The maximum cable length for a line must
not exceed 20 m.
156718
157025
next module
direct plug
blind plug
stacklight
M12, 5-pin,
male
M12, 5-pin,
female
157024
MGB2-L...
MCM-...
direct plug
cable connect
157028
157029
next module
cable connect
(M12, 5-pin,
female)
156718
157025
next module
direct plug
blind plug
157028
next module
cable connect
(M12, 5-pin,
female)
Figure 17: Connecting modules
Table 2: Overview of module connectors