37
2104766-13-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-AZ-AES-…
EN
Terminal assignment
Read head with connection cable
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
50 x 50 x 20.2
mm
Weight
0.08
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA or CES-A-BCA
Assured release distance S
ar
-
-
47
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured operating distance distance S
ao
10
-
-
- Switching hysteresis
2
3
-
In combination with actuator CES-A-BQA on evaluation unit CES-AZ-…-01B
Assured release distance S
ar
-
-
60
mm
Actuating range with vertical approach direction
Center offset m = 0
1)
- Switch-on distance
-
23
-
- Assured operating distance distance S
ao
16
-
-
- Switching hysteresis
2
3
-
Actuating range with side approach direction
Distance in x direction = 10 mm
- Switch-on distance
-
28
-
- Assured operating distance distance S
ao
24
-
-
- Switching hysteresis
1
1.3
-
Connecting cable
-
-
25
m
1) These values apply to surface installation of the read head and the actuator.
H11 H12
SH1
BN
WH
1
4
3
Shield
Read head
Evaluation unit
CES-AZ-AES-…