(Translation of the original operating instructions) 2104766-13-08/20
11.2. Evaluation unit CES-AZ-AES-02B
Ì
Housing for rail mounting, IP20
Ì
Relay output
Ì
2 read heads can be connected
Dimension drawing
45
99
114
H1
H2
24
Y2
O2
Y1
O1
23
STATE OUT DIA
+UB
0V
SH1
SH2
H12
H22
H11
H21
14
DIA
J2
TST
J1
13
S
CES - AZ
S
Y
Safety Unit
RESET
Unicode
5
6
1
2
Suitable for 35 mm mounting rail according to EN 60715
Switching characteristics
Ì
2 safety outputs with 2 NO contacts each
(relay outputs)
Ì
2 door monitoring outputs (semiconduc-
tor outputs, not safety outputs)
Important!
The plug-in screw terminals are not included (see chapter
12. Ordering information and accessories
).
Approvals
13
14
23
24
24 V
O 1
13
14
23
24
24 V
O 1
24 V
O 2
24 V
O 2
Guard
closed
(all actuators detected)
open
(e.g. actuator 1 not in the actuating
range)
Read head 1
Actuator 1
Read head 1