45
2104766-13-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-AZ-AES-…
EN
11.16. Actuator CES-A-BDA-20
Ì
Round design
∅
20 mm
Ì
In combination with read head CES-A-LNA…/CES-A-LCA…
Dimension drawing
∅
20
2,2
Active face
Active face
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
PC plastic
Dimensions
∅
20 x 2.2
mm
Weight
0.0008
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67
Installation orientation
Active face opposite read head
Power supply
Inductive via read head