Non-Contact Safety System CES-AZ-AES-…
EN
Technical data for CES-AZ-AES-02B
Parameter
Value
Unit
min.
typ.
max.
Housing material
PA6.6 plastic
Dimensions
114 x 99 x 45
mm
Weight
0.25
kg
Ambient temperature at U
B
= DC 24 V
-20
-
+55
°C
Atmospheric humidity, not condensing
-
-
80
%
Degree of protection
IP20
Degree of contamination
2
Mounting
Mounting rail 35 mm according to EN 60715 TH35
Number of read heads
Max. 2 read heads per evaluation unit
Connection cross-section (plug-in connection terminals, coded)
0.25
-
2.5
mm²
Operating voltage U
B
(regulated, residual ripple < 5%)
21
24
27
V DC
For the approval according to
the following applies
Operation only with UL class 2 power supply or equivalent measures
Current consumption I
B
(with relay energized)
1)
-
150
-
mA
External fuse (operating voltage U
B
)
0.25
-
8
A
Safety contacts
2 (relays with internally monitored contacts)
Switching current (relay outputs)
mA
- at switching voltage AC/DC 21 … 60 V
1
-
300
- at switching voltage AC/DC
5 … 30 V
10
-
6000
- at switching voltage AC
5 … 230 V
10
-
2000
Switching load according to
Class 2 max. 30 V AC/Class 2 max. 60 V DC
120 V AC 3 A / 240 V AC 1.5 A
External fuse (safety circuit) according to EN 60269-1
6 AgG or 6 A circuit breaker (characteristic B or C)
Utilization category according to EN 60947-5-1
AC-12 60 V 0.3 A / DC-12 60 V 0.3 A
AC-12 30 V 6 A / DC-12 30 V 6 A
AC-15 230 V 2 A / DC-13 24 V 3 A
Rated insulation voltage U
i
250
V
Rated impulse withstand voltage U
imp
4
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-2
Mechanical operating cycles (relays)
10 x 10
6
Switching delay from state change
2)
- 2 actuators activated
-
-
290
ms
- 1 actuator activated
-
-
210
Discrepancy time of the operating points of both relays
(with 2 activated actuators)
-
-
25
ms
Manual start operating mode
- Start button actuating duration
250
-
-
ms
- Start button response delay
-
200
300
Current via feedback loop Y1/Y2
5
8
10
mA
Permissible resistance via feedback loop
-
-
600
W
Ready delay
3)
-
10
12
s
Dwell time
4)
3
-
-
s
Switching frequency max.
5)
-
-
0.25
Hz
Repeat accuracy R acc. to EN IEC 60947-5-3
≤
10
%
Monitoring outputs (diagnostics DIA, door monitoring outputs
O1…O2, semiconductor output, p-switching, short circuit-pro-
tected)
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
20
mA
Start button input S, test input TST
- Input voltage
LOW
0
-
2
V DC
HIGH
15
-
U
B
- Input current
HIGH
5
8
10
mA
EMC protection requirements
Acc. to EN 60947-5-3
Reliability values acc. to EN ISO 13849-1
as a function of the switching current at 24 V DC
≤
0.1 A
≤
1 A
≤
3 A
Category
4
Performance Level (PL)
e
PFH
D
1.9 x 10
-8
Mission time
20
years
Number of switching cycles/year
760 000
153 000
34 600
Diagnostic coverage DC
99
%
MTTF
D
136
years
1) Without taking into account the load currents on the monitoring outputs.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum OFF time for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements
in accordance with EN 60947-5-3, the OFF time can increase to max. 430 ms. After a brief actuation < 0.4 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation.
3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set to LOW potential during the ready delay. For the visual indication of the delay, the green
STATE LED flashes at a frequency of approx. 15 Hz.
4) The dwell time is the time that the actuator must be outside the actuating range.
5) In case of monitoring with feedback loop, the actuators must remain outside the actuating range, e.g. with a door open, until the feedback loop is closed.