41
2104766-13-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-AZ-AES-…
EN
11.12. Actuator CES-A-BSP
Ì
Optimized for aluminum profile mounting
Dimension drawing for CES-A-BSP
97,1
10
57,5
Ø 5,2
18,1
6
5
R2
Active face
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
PA6 GF30
Weight
0.02
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP67
Installation orientation
Active face opposite read head
Power supply
Inductive via read head