39
2104766-13-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-AZ-AES-…
EN
Terminal assignment
Read head with plug connector
H11 H12 SH1
1
3
4
BN
WH
Shield
View on the plug
connector of the
read head
Evaluation unit
CES-AZ-AES-…
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Nickel-plated CuZn housing sleeve
Plastic PBT GF20 cap
Dimensions
M12 x 1, length 38
mm
Weight (incl. 10 m cable)
0.2
kg
Ambient temperature
-25
-
+85
°C
Ambient pressure
(only of active face in installed condition)
-
-
10
bar
Degree of protection
IP67/IP69/IP69K
Installation orientation
Any
Method of operation
Inductive
Power supply
Via evaluation unit
Connection
M8 plug connector, 3-pin
Connecting cable
-
-
15
m
In combination with actuator CES-A-BMB
Assured release distance S
ar
-
-
10
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
-
5
-
- Assured operating distance distance S
ao
3.5
-
-
- Switching hysteresis
0.1
0.3
-
In combination with actuator CES-A-BDA-20
Assured release distance S
ar
-
-
26
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
2)
-
9
-
- Assured operating distance distance S
ao
6
-
-
- Switching hysteresis
1
1.8
-
In combination with actuator CES-A-BDA-18
Assured release distance S
ar
-
-
21
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
3)
-
9
-
- Assured operating distance distance S
ao
6
-
-
- Switching hysteresis
0.5
1
-
In combination with actuator CES-A-BBA
Assured release distance S
ar
-
-
25
mm
Actuating range for center offset m = 0
1)
- Switch-on distance
3)
-
8
-
- Assured operating distance distance S
ao
5
-
-
- Switching hysteresis
1
1.83
-
1) These values apply to surface installation of the read head in steel.
2) A distance of s = 4 mm must be maintained for a side approach direction.