Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
34
(translation of the original operating instructions) MAN20001512-01-03/22
15. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
15.1. Technical data for key adapter CKS2-K-BP/BR-CC-FLX
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PA6-GF30 black
Dimensions
75 x 40 x 73
mm
Weight (device without connecting cable)
0.08
kg
Ambient temperature at U
B
= 24 V DC
-25
-
+55
°C
Storage temperature
-25
-
+70
Degree of protection
IP65/IP67 in installed state
Safety class
III
Degree of contamination
2
Installation orientation
On the front
Mounting cut-out acc. to DIN IEC 61554
33 x 68
mm
Connection
Connecting cable 15 cm (static bending radius 25 mm) with
CKS2-BP: plug connector M12, 5-pin
CKS2-BR: plug connector M12, 8-pin
Operating voltage U
B
24 -15 / +20%, regulated, residual ripple < 5%) (PELV)
V DC
Current consumption
40
mA
External fuse
(operating voltage)
0.25
-
8
A
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
FO1A
/U
FO1B
1)
HIGH
U
FO1A
U
B
-4
-
U
B
V DC
HIGH
U
FO1B
LOW
U
FO1A
/U
FO1B
0
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Off-state current I
r
≤
0.25
mA
Door position monitoring output OD/C
1)
p-switching, short circuit-proof
- Output voltage
HIGH
U
B
-1.5
-
U
B
V DC
LOW
0
-
1
- Switching current
1
-
50
mA
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Conditional short-circuit current
100
A
Shock and vibration resistance
Acc. to EN IEC 60947-5-3
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay
-
CKS2-BP: 2
CKS2-BR: 5
-
s
Risk time for single device
-
-
125
ms
Risk time extension per device in series connection
-
-
10
ms
Reaction time
2)
27.4
ms
Reaction time extension per device in series connection
6.7
ms
Turn-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test pulse duration
0.3
ms
Test pulse interval
Approx. 100
ms
Reliability values acc. to EN ISO 13849-1
3)
Category
4
Performance Level
PL e
PFH
D
6 x 10
-10
/ h
Mission time
20
years
Reliability values acc. to EN 62061:2005/A2:2015
SILCL3
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) The reaction time is the time until the moment when at least one of the outputs (FO1A or FO1B) switches off when the key is removed from the actuating range, given compliance with all manufacturer’s
specifications.
3) Refer to the declaration of conformity in chapter
for the issue date.